 | Single Zone Baseboard Controller
The single zone WZ_LVS250 controls one zone
of baseboard heating accurately to within a
few tenths of a deg.c. The Walker Temperature
Predictor in the software compensates for self
heating and wall effects to ensure stable control.
The WZ_LVS250 responds to a knob setpoint or
a supervisory command sent over the wireless
network. The integral motion detector can turn
down the heat based on occupancy to save
energy.
MODELS:
WZ_LVS250 -- 80 to 250 VAC
WZ_LVS25 -- 25V or Hydronic Controller
For more info on the WZ_LVS250 and WZ_LVS25 please visit the Home Control Products page or contact us at sales@walkersys.com
|
|
| Multiple Zone Wireless Master Control Box
For multiple zone baseboard control, the
controllers are linked by a wireless network
“master” controller that determines system
operation. The WZ_TERMINAL_1 allows operator
input or a contact closure to trigger the “on” state
of the controllers in the attached wireless system.
When the switch is “on” the WZ_TERMINAL_1
transmits an “on” command to all the controllers
in the network. When the LVSTAT250 controllers
are “on”, they control to the setpoint knob and
when “off” control to the preset low temperature.
The WZ_TERMINAL_1 can be triggered to
Occupied Mode by:
1. Locally or over the internet using the Browser Based Front End on your smartphone or computer.
2. Pushing a button on the WZ_TERMINAL_1
3. Contact closure from a remote switch or home
control system.
For more info on the WZ_TERMINAL_1 please visit the Home Control Products page or contact us at sales@walkersys.com |
|


|
My Home Heating – Browser Based Front End
View a sample of the embedded browser based Front End
The “My Home Heaingt” system can be configured to control multiple zones with various strategies
and options. This browser based Work Station can be viewed and adjusted by any internet capable devise.
Some of the basic functions of the My Home Heat Work Station are:
Occupied/Unoccupied State
When the system is set to Unoccupied state, The
WZ_TERMINAL commands all the WZ_LVSTATS to
use the Unoccupied setpoint. When the system is
set to Occupied state, the WZ_LVSTATS revert to
their KNOB setpoint. By doing this there is no need
to change any room setpoint once you are happy
with the temperature for Occupied mode.
Unoccupied Setpoint
The Unoccupied temperature setpoint can
be fixed or based on outdoor temperature, so
that as it gets colder outside the unoccupied
temperature setpoint is adjusted higher to give
insurance against power outages. This can be toggled by motion or user input
Minimum and Maximum Setpoint The minimum and maximum setpoints can be set
for each zone. These override the knob setpoint.
This is useful for keeping renters from turning
up the heat to high or maintaining a minimum
setpoint.
Schedule
Set day and night time schedules during
occupied mode. If you are away during the day,
or not using some areas, there is no point heating
empty spaces. |
 |
Installed for 3 years in the Villiage at Mt. Washington Ski Resort on Vancouer Island. B.C. Canada.
For information see our Mt. Washington Flyer |